티피링크 도매판매점 아델시스템

티피링크 유무선공유기 CCTV 무선AP Archer Tapo DECO VPN라우터 OmadaSDN컨트롤러 스위치 POE스위치 무선랜카드 USB허브 LED 랜카드 LED전구 블루투스

화웨이

아델시스템_화웨이 S310-48T4S

아델시스템 2024. 6. 10. 08:56

Huawei Campus Fixed Switch

S310-48T4S

Basic Information
Part Number
98012203
Model
S310-48T4S
Description
S310-48T4S (48*10/100/1000BASE-T ports, 4*GE SFP ports, AC power)
Technical Specifications
Chassis material
Metal
Height [mm]
43.6 mm
Depth [mm]
220.0 mm
Wide [mm]
442.0 mm
Chassis height [U]
1
Weight with packaging [kg(lb)]
3.59 (7.91)
Weight without packaging [kg(lb)]
2.71 (5.97)
Maximum power consumption [W]
52.05
Typical power consumption [W]
44.9
Heat dissipation mode
Air cooling for heat dissipation, intelligent fan speed adjustment
Maximum heat dissipation [BTU/hour]
177.6
Typical heat dissipation [BTU/hour]
153.2
Power supply mode
AC built-in
Input voltage range [V]
AC input: 90 V AC to 264 V AC; 45 Hz to 65 Hz
Rated input voltage [V]
AC input: 100–240 V AC; 50/60 Hz
Maximum input current [A]
1.6 A
Number of power slots
0
Number of card slots
0
Memory
2 GB
Flash memory
Physical space: 1 GB
Redundant power supply
Not supported
Types of fans
Built-in
Noise at normal temperature (acoustic power) [dB(A)]
46.6
Noise at normal temperature (acoustic pressure) [dB(A)]
34.6
Airflow direction
Air intake from left and air exhaust from right
Storage temperature [°C(°F)]
–40°C to +70°C (–40°F to +158°F)
Long-term operating temperature [°C(°F)]
-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.)
Restriction on the operating temperature variation rate [°C(°F)]
When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). Devices cannot start when the temperature is lower than 0°C (32°F). The operating temperature ranges from –5°C (23°F) to +45°C (113°F) when optical modules with transmission distances greater than or equal to 60 km are used. The device does not support dying gasp when the ambient temperature is higher than 40°C (104°F).
Long-term operating relative humidity [RH]
5% RH to 95% RH (non-condensing)
Storage altitude [m(ft.)]
0-5000 m (0-16404 ft.)
Long-term operating altitude [m(ft.)]
0–5000 m (0–16404 ft.)
MTBF [year]
40.61
MTTR [hour]
2
Availability
> 0.99999
Maximum number of physical ports on the entire device
52
Maximum number of 100GE ports
0
Maximum number of 40GE ports
0
Maximum number of 25GE ports
0
Maximum number of 10GE ports
0
Maximum number of GE ports
52
Maximum number of FE ports
48
Downlink ports
48 x 10/100/1000BASE-T ports
Uplink ports
4 x GE SFP ports
1000M optical interface
4
1000M electrical interface
48
USB
Not supported
Console port
RJ45
Eth Management port
Not supported
Service port surge protection [kV]
Common mode: ±7 kV
Power supply surge protection
Differential mode: ±6 kV; common mode: ±6 kV
RPS input
Not supported
PoE
Not supported

'화웨이' 카테고리의 다른 글

아델시스템_화웨이 S310-24T4S  (2) 2024.06.10
아델시스템_화웨이 S310-24P4S  (0) 2024.06.10
아델시스템_화웨이 S220-48T4X  (0) 2024.06.10
아델시스템_화웨이 S220-48T4S  (0) 2024.06.10
아델시스템_화웨이 S220-48P4X  (0) 2024.06.10