Huawei Campus Fixed PoE+ Switch
S110-24LP2SR
Basic Information
|
|
Part Number
|
98012198
|
Model
|
S110-24LP2SR
|
Description
|
S110-24LP2SR (24*10/100/1000BASE-T ports, 2*GE SFP ports, PoE+, AC power)
|
Technical Specifications
|
|
Chassis material
|
Metal
|
Height [mm]
|
43.6 mm
|
Depth [mm]
|
260.0 mm
|
Wide [mm]
|
442.0 mm
|
Chassis height [U]
|
1
|
Weight with packaging [kg(lb)]
|
3.7 (8.16)
|
Weight without packaging [kg(lb)]
|
3.2 (7.05)
|
Maximum power consumption [W]
|
Without PoE: 24 W Full PoE load: 165 W (PoE: 124 W)
|
Typical power consumption [W]
|
24
|
Heat dissipation mode
|
Natural heat dissipation
|
Maximum heat dissipation [BTU/hour]
|
Without PoE: 81.89 Full PoE load: 563
|
Typical heat dissipation [BTU/hour]
|
81.89
|
Power supply mode
|
AC built-in
|
Input voltage range [V]
|
AC input: 90 V AC to 300 V AC; 47 Hz to 63 Hz
|
Rated input voltage [V]
|
AC input: 100–240 V AC; 50/60 Hz
|
Maximum input current [A]
|
3 A
|
Number of power slots
|
0
|
Number of card slots
|
0
|
Memory
|
-
|
Flash memory
|
-
|
Redundant power supply
|
Not supported
|
Types of fans
|
None
|
Noise at normal temperature (acoustic power) [dB(A)]
|
Noise-free (no fans), < 30
|
Noise at normal temperature (acoustic pressure) [dB(A)]
|
Noise-free (no fans), < 20
|
Airflow direction
|
-
|
Storage temperature [°C(°F)]
|
–40°C to +70°C (–40°F to +158°F)
|
Long-term operating temperature [°C(°F)]
|
0°C to 40°C (32°F to 104°F) at an altitude of 0-1800 m (0-5906 ft.)
|
Restriction on the operating temperature variation rate [°C(°F)]
|
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).
|
Long-term operating relative humidity [RH]
|
5% RH to 95% RH (non-condensing)
|
Storage altitude [m(ft.)]
|
0-5000 m (0-16404 ft.)
|
Long-term operating altitude [m(ft.)]
|
0–5000 m (0–16404 ft.)
|
MTBF [year]
|
42.92
|
MTTR [hour]
|
2
|
Availability
|
> 0.99999
|
Maximum number of physical ports on the entire device
|
26
|
Maximum number of 100GE ports
|
0
|
Maximum number of 40GE ports
|
0
|
Maximum number of 25GE ports
|
0
|
Maximum number of 10GE ports
|
0
|
Maximum number of GE ports
|
26
|
Maximum number of FE ports
|
26
|
Downlink ports
|
24 x 10/100/1000BASE-T ports (124 W PoE+)
|
Uplink ports
|
2 x GE SFP ports
|
USB
|
Not supported
|
Console port
|
Not supported
|
Eth Management port
|
Not supported
|
Working mode
|
- Standard mode - Port isolation - Uplink aggregation - Flow control disabling
|
MAC address entry
|
8K
|
Service port surge protection [kV]
|
Common mode: ±4 kV
|
Power supply surge protection
|
Differential mode: ±6 kV; common mode: ±6 kV
|
RPS input
|
Not supported
|
PoE
|
Supported
|